Dynex DS2 Automated ELISA Processing System

Contact us with any questions.

Thank you!

 Request Quote

Description

Dynex DS2 Automated ELISA Processing System 

Run any assay from any vendor

  • Fully automated open system
  • Ability to bring in tests that are currently being sent out
  • Automated sample distribution, incubation, reagent addition, washing and detection steps of assays as defined by the manufacturer. The lab can customize assay parameters, assay steps, OD read settings, result calculations, quality control checks and report formats with ease

Reliable workload scheduling

  • For the past 2 years DYNEX DS2 has achieved 98.5 uptime when mean time between failure target is set at 250 days
  • Schedule your preventive maintenance during slow period
  • Electronic Signature Pipetting (ESP) is a sophisticated technique used by the DS2 for detection of gross pipetting errors often caused by the presence of particulate matter, clots, foam, or bubbles in the sample. Insufficient sample transfer can therefore be detected and reported to the operator during a run
  • Prevent unscheduled down time

Saves Space

  • The DS2 system footprint is less than four square feet of linear counter space to process up to two 96-well microplates and 100 specimens making it ideal for lab’s expanding workload
  • Utilize the same linear space as manual incubator and reader

The innovative DS2 is designed for clinical, research and industrial labs that want to enhance their processes through automation. Installed in over 3,500 labs worldwide, the DS2 is the solution for the rigorous, repeatable analyses required in critical applications including immunology, infectious disease, hormone, allergy, blood-chemistry, drugs-of-abuse testing, food safety, forensics, and environmental testing among others.

Specifications

Physical Specifications

Dimensions      Metric          Non Metric

Width:            54 cm            21 in

Depth:           68 cm             27 in

Height:           66 cm             26 in

Footprint:         0.36 sq m         3.9 sq ft

Bench Weight:      48 kg            105 Ib

Ship Weight:        78 kg             170lb

Noise:              Noise output     < 78 dB

System Specifications

Number of Plates:              2

Sample Capacity:              100 per load

Continuous Sample Loading:     Yes

Sample Tube Size:             10 mm – 16 mm diameter

40 mm – 100 mm height

Number of Reagents:          Up to 8 (25 mL tubes)

Up to 10 (15 mL tubes)

Number of

Standard/Control Bottles:       24 (2 mL vials)

Assays per Plate:               Up to 12

Dilution Wells Capacity:         Up to 96 deep-well strips (12 x 8)

Sample Tip Capacity:            216 tips (2 x 108)

Reagent Tip Capacity:            20 tips

Reader Specifications

Photometric Range:            0.100 – 3.0 OD

Spectral Range:               405 nm – 690 nm

Filter Slots:                  6 wavelength

Precision:                   < 1% CV (< 2.0 OD)

< 2% CV (2.0 – 3.0 OD)

Accuracy:                   ± 0.005 OD or 2.5

                                   (0.000 – 3.000 OD) whichever is greater

Read Time:                 < 30 sec (single wavelength)

Washer Specification

Manifold Configuration:             8-way

Programmable Volumes:           50 µL – 1,000 µL

Wash Buffer Capacity:             2 wash bottles at 2 L, with level-sensing

Residual Wash Volume:            < 3 µL with super sweep

Dispense Precision:               ≤ 5% CV (with 300 μL in a 96 well plate)

Waste Container:                 1 x 1.5 L

Incubator Specifications

Number of Incubators:             2

Temperature Range:               Ambient + 4° C to 40° C

Temperature Accuracy:            ± 1° C across plate @ 37° C

Shaking:                             Independent linear motion

14 – 20 Hz (periodic or continuous)

Temperature Monitoring:               Yes

Reagent Pipetting Specifications

Reagent Tip Size:                    1,300 µL

Reagent Pipetting Volume:            20 μL – 1,000 μL

Precision, Reagent Tip:               < 3% CV at any operating volume above

20 uL (single-shot mode)

Sample Pipetting Specifications

Sample Tip Size:                      300 μL

Sample Pipetting Volume:              10 μL – 250 μL

Sample Pipetting Precision:            < 3% CV at any operating volume above

10 uL (single-shot mode)

Dilution Range:                      1 part in 199 one-stage dilution

1 part in 39,601 two-stage dilution

Process Security

Liquid Level Sensing:                 Yes (reagents, controls and samples)

Level Sensor System:                 Pressure di erential

Clot Detection:                      Yes

Dispense Anomaly Detection:          Yes

Tip Detection:                       Yes

Electronic Signature Pipetting:          Yes

Alarms:                            Yes

 

Software

Controlling Software:               DS-Matrix

Work Protocols (Assays):            Unlimited

Data Processing:                   Quantitative and qualitative

Levey-Jennings:                   Yes

Westgard Rules:                   Yes

Process Reporting:                 Event log + error log

Automatic Error Recovery:           Yes

Password Access Control:            Yes

Privacy Overview

This privacy policy discloses the privacy practices for International Diagnostic. This privacy policy applies solely to information collected by this website. It will notify you of the following:

  1. What personally identifiable information is collected from you through the web site, how it is used and with whom it may be shared.
  2. What choices are available to you regarding the use of your data.
  3. The security procedures in place to protect the misuse of your information.
  4. How you can correct any inaccuracies in the information.

 

Information Collection, Use, and Sharing

We are the sole owners of the information collected on this site. We only have access to/collect information that you voluntarily give us via email or other direct contact from you. We will not sell or rent this information to anyone.

We will use your information to respond to you, regarding the reason you contacted us. We will not share your information with any third party outside of our organization, other than as necessary to fulfill your request, e.g. to ship an order.

Unless you ask us not to, we may contact you via email in the future to tell you about specials, new products or services, or changes to this privacy policy.

 

Your Access to and Control Over Information

You may opt out of any future contacts from us at any time. You can do the following at any time by contacting us via the email address or phone number given on our website:

  • See what data we have about you, if any.
  • Change/correct any data we have about you.
  • Have us delete any data we have about you.
  • Express any concern you have about our use of your data.

 

Security

We take precautions to protect your information. When you submit sensitive information via the website, your information is protected both online and offline.

Wherever we collect sensitive information (such as credit card data), that information is encrypted and transmitted to us in a secure way. You can verify this by looking for a closed lock icon at the bottom of your web browser, or looking for "https" at the beginning of the address of the web page.

While we use encryption to protect sensitive information transmitted online, we also protect your information offline. Only employees who need the information to perform a specific job (for example, billing or customer service) are granted access to personally identifiable information. The computers/servers in which we store personally identifiable information are kept in a secure environment.

Updates

Our Privacy Policy may change from time to time and all updates will be posted on this page.

If you feel that we are not abiding by this privacy policy, you should contact us immediately via telephone at 951-296-1266.